A typical installation will use THHN type wire. SMFs are included with all Mobile FXs. FX & VFX Series Inverter/Charger System Installation & Programming Manual, 08/26/05 Tel 360 435 6030 Fax 360 435 6019. Connecting more This type of FX system can continuously power 4-7.2KW of loads depending on which model is used. All FXs can be mounted in any position. Personal Precautions While Working with Batteries. AGS can start and stop the generator daily at specified times. %PDF-1.4 % There is a 2-inch TSC cut-out on the plastic box to allow it to be used with the FX-DCA (DC CONDUIT ADAPTER) The FX-DCA allows the connection of, HUB COMMUNICATION MANAGER The HUB communication manager allows the MATE to control and monitor a maximum of ten OutBack products. by Ana Wed Jan 08, 2020 9:03 pm, Post . This manual contains important instructions for the OutBack FX series inverter/charger system with the software which allows classic (two FX's in series), parallel and series/parallel stacking of two to ten FX's for higher power and/or higher voltage systems. INTELLIGENT BATTERY CHARGER Advanced charging algorithms provide fast recharging while increasing battery life. 2. For Mobile installations, OutBack includes a stud When the FXs are connected in series for 120/240 VAC, the X-240 autotransformer can be connected to the AC output to allow both of In addition to Place the flat washer, lock washer and nut on top of the battery terminal lug. FXs used in home No terminals or lugs are required for hook-up of the AC wiring. FX has been programmed using the MATE, the MATE can be disconnected. The. The side of the ACA can be used to add an AC outlet I hope you are having a great holiday season! There are diagrams for a single FX, two FXs in series or series/parallel (see NOTE below), two FXs in parallel. This email address is being protected from spambots. the HUB. Our goal is to provide you with a quick access to the content of the user manual for Outback Power Systems Inverter/Charger FX2348ET. 1. wire is required in order to handle the 60 amp capacity of the non-Mobile FXs AC transfer switch. current requirement. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Outback Power Systems Inverter/Charger FX2348ET. After the FX has been powered down through the DC breaker, it can then be removed for servicing or replacement without It could short-circuit the batteries or other electrical Each FX produces 230 VAC (volts of AC) but multiple FXs can be configured in parallel or 3-phase and these configurations may produce different voltages on the AC output legs. These terminals are not operational at this time. The OutBack FX Series of inverter/chargers have an auxiliary ("AUX") 12-volt output which can drive various devices. 0000006728 00000 n the AC source and to the AC loads must handle 100 amps AC or more. All other AC wiring must handle a capacity of 50 amps AC or The diagrams show the proper breakers and wiring for the AC side of the installations as well as connections to the HUB or MATE. 0000014520 00000 n Itwillstopiftheloadsgobelowacertainamountforacertaintime(all. the CAT-5 cable that is included with the MATE and the HUB. separate AC input breaker. Page 8: Welcome To Outback Power Technologies Voltages outside of this range may damage AC, loads connected to the FXs AC output terminals. See the STACKING INFORMATION section of the manual OutBack products include true sine wave inverter/chargers, maximum power point tracking charge controllers, and system communication components, as well as . 0000002973 00000 n This procedure describes the removal of all circuit boards in an FX-class or FXR-class inverter. trailer <]>> startxref 0 %%EOF 200 0 obj<>stream Use two FXs wired in a series configuration or the addition of an X-240 The FX includes an AC wiring compartment with both a removable cover and AC conduit plate. ~``IX7\Kz6-DBn|lSMOK`-M WcNmPHu96 )VgMMoy document.getElementById('cloak9d773456345917a13245c7b0659e2427').innerHTML = ''; The HUB communication manager allows the MATE to control and monitor a maximum of ten OutBack products. Authorization to Mark UL1741 SA (FXR A Series) Using Inverter Input Modes for Smart Grid Management. The AC transfer switch transfers the AC input power through the FX to the AC loads connected to the AC, output of the FX. See the. the FX system. chassis of the inverter. The ACA can be used to connect the FX to the PS2AC, PS4AC or 2 conduit. It sounds like your generator is wired to your inverter output. For instructions on mounting, see the MOUNTING section of this manual. that the model number indicates. 0000003233 00000 n If not all boards need to be replaced, the installer may proceed through the steps that are required, and ignore the subsequent disassembly. Fabricant: Outback Power Systems, Modle: FX2024ET, Type de document: Manuel d'utilisation, Catgorie: Chargeur, Nombre de pages: 59 . There is a 2-inch TSC cut-out on the plastic box to allow it to be used with the PSAC or PS2AC disconnect enclosure. In a stacked configuration, the Master FX must be plugged into port #1 of Locating the FX in a cool location will ensure the highest efficiency and power capacity. Keep a supply on hand in the area of the batteries. The first test is to try to eliminate internal faults in the Outback inverters and wiring. Typically, the Turbo Kit adds 300-500 watts of power to the FX. 5. considered to be low voltage / limited energy circuitry. In this case the AUX can directly or indirectly send commands to the generator. Connection of 2-inch Powerful: up to 125 amps. This plastic box slips into grooves on the AC end of the FX. Wiring to these terminals must meet requirements of the National Electric Code (NEC). Cable must meet the requirements of the National Electrical Code. mounted fuse which can be connected directly to the positive DC terminal of the FX it is available in 100, 175 and 250 amp Outback Power Systems Inverter/Charger FX2348ET, User manual Outback Power Systems Inverter/Charger FX2348ET, Instruction d'utilisation Outback Power Systems Inverter/Charger FX2348ET, Bedienungsanleitung Outback Power Systems Inverter/Charger FX2348ET, Outback Power Systems Inverter/Charger FX2348ET, Outback Power Systems Inverter/Charger FX2348ET, Manual de instrucciones Outback Power Systems Inverter/Charger FX2348ET, Manual do usurio Outback Power Systems Inverter/Charger FX2348ET, Instrukcja obsugi Outback Power Systems Inverter/Charger FX2348ET, Outback Power Systems GRID-INTERACTIVE GVFX, Outback Power Systems INTERNATIONAL SERIES GFX1312E, Outback Power Systems GRID-INTERACTIVE GTFX, Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. For instance, an FX. All wiring methods are to be made in accordance with th, INDICATORS / CONTROL WIRING The AC wiring compartment also encloses the green terminal block used for the low voltage control wiring. To start viewing the user manual Outback Power Systems Inverter/Charger FX2348ET on full screen, use the button Fullscreen. For a Mobile FX system, 30A input breakers should be used due to the maximum AC input pass-through rating of the Mobile DCA and DCC (or Turbo) are required. breaker box), DCAs (DC Conduit Adapter), DCCs (DC Compartment Cover), and ACAs (AC Compartment Adapter). Electrical Codes (NEC) installation requirements. For installations where the FX may be exposed to water spray a sealed FX must be used. If mounted with the base down, water cannot be allowed to The Turbo Kit adds 1 (25mm) additional height to achieve a total height of 12.87 (327mm), Shown below are complete systems of OutBack FXs for indoor installations. Turning off the FX may not Some inverters (and charge controllers have a "ground fault detect" circuit you may be able to "hack") have an input line which is an "inhibit" (remote on/off) or programmable input that may be used for on/off. FX SYSTEM CONFIGURATION SERIES OR SERIES/PARALLEL DUAL FX SYSTEM. Each FX has a maximum continuous output power it can deliver. DO NOT PUT ANY WASHERS BETWEEN THE TERMINAL MOUNTING SURFACE AND. Web the outback inverter/charger models listed in this document are validated through compliance testing. AGS can run the generator for brief periods, to keep it from being, inactive. The system with four FXs is shown mounted to the For this type of installation, use of OutBack Power Systems PS2 system is recommended. 0000000756 00000 n parts that may result in fire or explosion. for more info. All other AC wiring must handle a capacity of 50 amps AC or Closing the switch for that section did the trick and returned power to camp. In hot climates or when the FX is the primary charging device, the chances of the FX overheating are heightened. These are the same It is used to select the minimum reasonable battery capacity. Keep the cables together as much as possible and Place the lug, fuse and fuse nut This product is only serviceable by qualified personnel. If your, generator cannot continuously produce the AC Input Limit or you are connecting to an AC input source that has a breaker. var addy_text9d773456345917a13245c7b0659e2427 = 'E-Mail Us';document.getElementById('cloak9d773456345917a13245c7b0659e2427').innerHTML += '
'+addy_text9d773456345917a13245c7b0659e2427+'<\/a>'; 60 Hz Grid-Hybrid Renewable Energy System, Models: FXR3048A and VFXR3648A - FXR2524A and VFXR3524A - FXR2012A and VFXR2812A - FXR2348E and VFXR3048E - FXR2024E and VFXR3024E - FXR2012E and VFXR2612E. These instructions detail how to remove and replace the following parts of any FX-class or, Control Printed-Circuit Board Assembly (PCBA), AC Printed-Circuit Board Assembly (PCBA), FET Printed-Circuit Board Assembly (PCBA), These instructions extend to all FX, FXR, VFX, VFXR, GTFX, GVFX, and GFX models, including all, 10mm socket with 12" extension & torque wrench, Power supply (9-volt batteries may be used), This procedure describes the removal of all circuit boards in an FX-class or FXR-class inverter. PS4AC or PS2AC disconnect enclosure or 2-inch conduit. Be extra cautious to reduce the risk of dropping a metal tool onto batteries. qualified renewable energy equipment electrician. FXR (A) Declaration of Conformity. This adapter extends Just wanted to post a quick update. In addition to the AC-IOB input/output bypass assembly, each FX has a by raysun Wed Jan 08, 2020 9:59 pm, Discussion about OutBack Inverters in Off Grid Applications. 0000000816 00000 n Verify that the fiber is securely inserted and the main circuit connections are tightened. provided on the sides of the cover to pry the cap off. 0000002647 00000 n The maximum distance Power Systems does not support 3-wire start generators; however, a 3-wire to 2-wire conversion kit is available from other sources. The hole of the battery cable lugs must Paste the shortcode from one of the relevant plugins here in order to enable logging in with social networks. Non-OutBack sensors may Outback Power FX Series Inverter Repair Parts Please select your Outback Power FX Series spare inverter parts model to find the available replacement parts. This adapter extends the AC wiring compartment to match the PSAC or PS2AC. This six position terminal block can be unplugged to make wiring easier and to simplify the removal and reinstallation of an inverter. through the AC-IOBs bypass breakers to the load bank. Headquarters:3767 Alpha WayBellingham, WA 98226 United States. Downloading to your computer - You can also download the user manual Outback Power Systems Inverter/Charger FX2348ET to your computer and keep it in your files. Exercise Start. If using a 3/8 hole, file this down to produce a 10mm hole. Thisfeature, Load Start. 08/26/05 Tel 360 435 6030 Fax 360 435 6019, MASTER ADJUST ONLY.. 28, FX & VFX Series Inverter/Charger System Installation & Programming Manual. These instructions are for use by qualified personnel who meet all local and governmental code requirements for licensing and training for the installation of electrical power systems with AC and DC voltage up to 600 volts. 0000005785 00000 n Fabricante: Outback Power Systems, Modelo: FX2024ET, Tipo de documento: Manual de instrucciones, Categora: Cargador, Nmero de pginas: 59. VDC at 1.0 amps (12 watts) maximum. If submerged, water can terminal block must be rated for at least 75. of large gauge cables (2/0 or 4/0 AWG) or larger is advisable to reduce losses and ensure high performance of the FX. s&PD$wG!I_e1ekk+k@/I,ulmT\Q*Q""6v| yfItR.KL`U=C(Mp;>?pkYl$lz>d.%BAj 4{Ot w'>AkTGJ!c0,;H"L4bG! h-C}Eo^AJ1C)>3rd/|=&MkX*(pgEw"D3(R{[nt[VfHo. Refer to the MATE manual for more information on the MATE. Currently the HUB comes in two types. The maximum DC current that can be produced is also shown below. Before using the FX, read all instructions and cautionary markings on (1) the FX, (2) the batteries and (3) all appropriate sections of this installation and operation manual. Inverter Controls The FX inverter has no external controls. This connection is to be made by the installer either in the AC service entrance or within the AC load distribution panel The LED is solid and the inverter must be turned off and then on to reset. The HUB-4 can connect up to four Outback products (FXs and/or MX-60s). However, external communication devices such as the OutBack MATE3 Also included is information on the maximum continuous power of the systems and proper DC breaker size, FX SYSTEM CONFIGURATION - PARALLELED DUAL FX SYSTEM Paralleled Dual FX System The following diagram illustrates a typical paralleled FX installation using two FXs. 3. For Mobile FXs, a 30A input breaker should be used due to the maximum AC input pass-through rating of the UL listed DC rated circuit breakers are available from OutBack Power Systems with amperages of 100, 175 and 250 amps DC. Notice of Copyright Check with your OutBack dealer for additional cables. The slave 470 uF (micro Farad) electrolytic capacitor (found at your local electronics shop) across the auxiliary output will solve this problem. When the generator is running the Turbo Kit is also running. No additional fuses are required. BREAKERS OR FUSES WITHIN THE POSITIVE BATTERY CABLE. The AC wiring compartment also encloses the following items; a 6-port terminal block, an RJ-11 jack, an RJ-45 jack, a set of three Wash your hands with soap and warm water If you want to quickly view the content of pages found on the following pages of the manual, you can use them. opposite end of the FX from the AC wiring compartment. standard CAT-5 type cabling. This is the maximum DC current that the FX will draw from the battery when starting very large AC loads. Place the lug, washers and nut in the following order: Lug, Flat Washer, Lock Washer, Nut. The maximum and default values for this setting are shown below. (with Outlet or Circuit power than the continuous rating of the FX may cause breakers to trip or the FX to shut off its AC output. by raysun Thu Dec 26, 2019 7:12 am, Post Thanks again! Certain criteria can override quiet time,for an emergency start. 8. OutBack Power Systems Export FX and VFX Inverter/Charger Installation and Programming Manual Document Revision 7.1 FX 2012ET - 2.0 kW / 12 VDC / 230 VAC / 50 Hz (Sealed + Turbo / Export) FX 2024ET - 2.0 kW / 24 VDC / 230 VAC / 50 Hz (Sealed + Turbo / Export) FX 2348ET - 2.3 kW / 48 VDC / 230 VAC / 50 Hz (Sealed + Turbo / Export) VFX 2612E - 2.6 kW / 12 VDC / 230 VAC / 50 Hz (Ventilated / Export) VFX 3024E - 3.0 kW / 24 VDC / 230 VAC / 50 Hz (Ventilated / Export) VFX 3048E - 3.0 kW, Installation & Programming Manual FX & VFX E Series Inverter/Charger System Copyright 2003 OutBack Power Systems, Inc. nd 900-0027-2 19009 62 Ave NE, Arlington WA 98223 USA Page 2 Rev 7.1 06/08/06 Tel 360 435 6030 Fax 360 435 6019. DECLARATION OF CONFORMITY EU Declaration of Conformity According to ISO / IEC Guide 22 and EN 45014 Product Type: Power Inverter/Charger Product Model Numbers: FX2012E, VFX2612E, FX2024E, VFX3024E, FX2348E, VFX3048E, These products comply with the following EU directives: Electromagnetic Compatibility 89/336/EEC, Council Directive of 3 May 1989 On the approximation of the laws of member States relating to Electromagnetic compatibility Low Voltage Directive 73/23. Email: This email address is being protected from spambots. xV}4Y1#DaF^Na"i595TU"|LP$IT8={1t1y~`FrLbL(MA1q]Ia=!fZOP]A5Rx$k[VX%bK3.eud^=r7/6Ko}]A#xyf~7]UyRh]M++hgw sh},k{4WlZbw[{I>Yl]B-,Od9]f&]TyEx~GA/=fuXx305~D-=~Wy|bEKo[ XZ[rqSICva]%>*l`}L%&f.-C][9/T",sQv.3EBi-f${4?e_Mx],} e%*I8el=eR~4TC~g6` ,f1tS:Vm:SlBW^VP|FYOy!Q={T The HUB manages both the inter-FX communications and the MATE-FX communication. 2 Wiring to these terminals must meet requirements of the local electric code. A set-screw type box lug is provided near the DC terminals to allow the connection of an equipment grounding conductor for the metal heavy 120 VAC loads are powered by both of the FXs. Outback Power Systems GFX1312 40 pginas 1.29 mb; Battery Charger Outback Power Systems Inverter/Charger FX2012ET 59 pginas 2.26 mb; Battery Charger Outback Power Systems GFX1424 40 pginas 1.29 mb; Battery Charger Outback Power Systems Systems 24 pginas 1 mb; Battery Charger Outback Power Systems GVFX3648 2 pginas 0.18 mb; Battery Charger mechanisms. All other AC wiring must handle a capacity of 50 amps AC or more. 0000017190 00000 n Keep the MATE out of direct sunlight to make the display easier to view. This type This information is dependent on whether The following diagram illustrates a typical series FX installation using two FXs. required, increase the cable size to the next size as a minimum. Cabling 0000018146 00000 n The Battery LEDs operate at the following voltage levels: The Status LEDs operate under the following conditions: The left two terminals of the 6-port terminal block marked. 0000003164 00000 n The order of removal depicted here is: 1. These maximum DC currents can only There are other factors like cable losses that may reduce when the FX is the primary charging device, the chances of the FX overheating are heightened. BATTERY TEMP {REMOTE TEMPERATURE SENSOR (RTS)}, The OutBack FX has a 4 conductor phone RJ-11 modular jack located in the AC compartment for the connection of an optional Port 1, and the seven Slaves must be plugged into Ports 2-8. 0000003502 00000 n 0000004067 00000 n The diagrams show the proper breakers 20122023, manualsdir.comAll rights reserved. 2023 by ManualsBase.com. limits, it will back off the charging process to avoid overheating (and a shutdown of the FX). Iftheswitchisoff,it, Athree-wire-startgeneratorhasseparatecontrolsforstarting,andforrunning. After this split second the FX lowers this surge limit. It contains all of the One MATE system controller and display can be connected to the HUB. from the HUB to the MATE is completed using standard CAT-5 type ethernet cable with RJ45 modular 8 conductor jacks. Connection to the ground terminal is not required It is located behind the battery negative terminal on the top of the inverter casting. 4. protection in accordance with the National Electrical Code, ANSI/NFPA 70. wire (common neutral) branch circuits connected. There are diagrams for a single FX, two FXs in parallel, four FXs in parallel, and a 3-phase system. four FXs in series/parallel (see NOTE below), four FXs in parallel, and a 3-phase system. terminal mounted fuses and should always be used in conjuncture with a disconnect mechanism. 0000012842 00000 n 0000013859 00000 n The MATE must be connected to adjust any parameters or to display any meters. stacking, X-240 included). The following diagram illustrates a typical paralleled FX installation using two FXs. The programming will be saved within the FXs nonvolatile memory even if the FX is completely shut down. It fits on the Outback Inverter Manual. However, the troubleshooting information here is helpful regardless of the AC source. Locating the FX in a cool location will improve the operation and ensure the highest efficiency and power capacity. This manual is related to the following products. and third Slaves as OutBack L2 slaves (OB SLAVE L2). Enter your email address and check your inbox. be attained in the Bulk charging stage. and one or two of OutBacks AC rated OBDC circuit breakers (up to 70 amps max). In my own experience, if it's not plugged into port one, all kinds of weird and strange problems arise. The FX is approved for i, RATINGS NOMINAL SYSTEM AC VOLTAGE: This is the AC output voltage produced by an FX system. autotransformer if you are connecting to a 120/240 VAC multi wire system. VERY QUIET The sealed FX inverters are virtually silent. FXs. the above diagram the AC sources neutral conductor must go directly to the FXs AC NEUTRAL IN terminal or to a separate neutral Contact your dealer for information on qualified electricians. The Turbo Kit solves this problem by The DCC can be used available on either of the 120 VAC output circuits. The following diagram illustrates a typical single FX installation. EXTREMELY EFFICIENT Get more power out of your batteries - run larger AC loads longer. For automatic or advanced AC PCBA 3. communication manager is connected to this RJ-45 jack for stacking of the FXs and for efficient system performance. If battery acid contacts skin or clothing, wash immediately with soap and water. The location of the 2inch conduit opening matches the 2-inch knockouts provided in the PS4DC or For battery installation and maintenance: read the battery manufacturer's instructions prior to installation and operation. 1 All of the AC field wiring terminals are to be torqued to 30 inch-pounds (equivalent to 2.5 foot-pounds or b=R^[+n,tK"-;M )?|x*s rM + ^95GRBI%%C8UgP9wgmGQAay:?t -Pl*)j 'T"@L[a}d$#r`g<4]L7Gjdr o 5Xt4,h-#u8n'6fr=7js$ %|qB.? directing air over the casting and its fins, thus causing better convection cooling of the FX. When mounting an FX to a PS2MP or PS4MP, a star washer located under one of the four screws that connect the Use the OutBack FX Turbo Kit or DC12-FAN for cooling. by Ana Thu Dec 26, 2019 9:24 am, Post power to a sealed FX. The 6-port terminal block contains ports for Inverter & On/Off, AUX + & AUX , and 0000004986 00000 n AC) and/or an AC outlet through the knockouts provided. STACKING INFORMATION section of the manual for more info. The power available at these terminals is 12 5. This is the amount of AC Surge current that the FX will supply. cables connected to the FX. Before using the FX, read all instructions and cautionary markings on (1) the FX, (2) the batteries and (3) all appropriate sections The threads are M8 x 1.25. 3. from the HUB-4 to the FX or MX-60 should be less than 10 feet. information on the maximum continuous power of the systems and proper DC breaker sizes. Depending on the size of the surge, the FX can be overloaded for a of FX system can continuously power 8-14.4KW of loads depending on which model is used. Symbols Used WARNING: Hazard to Human Life Program the top FX as Master (1-2PH MASTER) and the lower FX as an OutBack L1 Slave (OB SLAVE L1). Tying or taping the cables together is also advisable. In Normal mode, the FXs AC hot outputs are Please refer to the programming section to adjust FX must be programmed through the MATE as a Classic Slave (series stacking, no X-240) or as OB Slave L2 (series/parallel If using the stud mounted fuse, the positive lug must have a hole of installations should use properly sized DC circuit breakers. standard with the HUB-10. Thus, the AUX would send a 12-volt signal to the coil of the relay. tasks. These are hard faults. An OBDC circuit breaker includes both overcurrent protection and When installing an FX with a PS4DC or PS2DC disconnect enclosure, both the A battery can DC circuit and the chassis of the FX is the responsibility of the installer. disconnection capability. All cabling from the FX and MX60 communication ports to the HUB is made with CAT-5 type ethernet cabling. 271 26 OutBack, The mounting plate will typically need to be bolted to the studs in a wall using at least four 1/4 or 5/16 lag bolts 2 long. All Mobile FX inverter/chargers are ETL listed to UL 458. FX inverters have status lights to indicate presence of AC input voltage and connection status. mount other components such as a DC current shunt. The FX System Configuration section shows diagrams of some typical system configurations using the FX. 0000002964 00000 n its starting battery while servicing it to prevent starting while servicing. Better performance will be achieved if it is mounted in a location which allows for air to circulate around the exterior of the casting. protection circuits. The programming will be saved within the The ACA may also be used for mounting two breakers OBDC breakers (rated for http://www.outbackpower.com/resources/t re-updates. The DCC is provided with all VFX inverter/chargers. busbar that is isolated from the FXs AC output neutral. accumulate around the FXs base. OUTBACK POWER SYSTEMS TROUBLESHOOTING (Pt.1) - YouTube 0:00 / 9:22 OUTBACK POWER SYSTEMS TROUBLESHOOTING (Pt.1) jwsolarusa 11K subscribers 3.5K views 3 years ago ELECTRONICS SUPPLY CO.,. sizes (part number SMF-XXX). A sealed FX that may be exposed to water A MATE must be connected You need JavaScript enabled to view it. Table 1 provides the specifications for the new outback fx2012emt, fx2024emt, and fx2348emt inverter/chargers. with or without the DCA. paper. 3. The signal powering the Turbo Kit fan comes from the auxiliary output of the FX. the auxiliary output, you can program the auxiliary output to GenAlert or use the Advanced Generator Start (AGS) system and parallel If this is the case, only one RTS is required for all devices plugged into the HUB. To do so, power down the entire system, then restart it with the AC output disconnected from the external loads. the AC conduit plate may or may not be used. FXs non-volatile memory even if the FX is completely shut down. This is the AC input sources frequency range of which the FX will accept and stay connected. All of the AC wiring to the AC terminals is to be torqued to 30 inch-pounds (equivalent to 2.5 foot-pounds or 3.4 Nm). the AC source and to the AC loads must handle 50 amps AC or more. Someone should be within range of your voice to come to your aid. FX SYSTEM CONFIGURATION SERIES/PARALLEL QUAD FX SYSTEM. 0000004876 00000 n - 3 Flexmate 80 charge controllers with Outback temperature compensation sensor - 2 Outback VFX3648 inverters - FlexnetDC charging controller 24 Outback 2700RE batteries and racking (2288 amp hour capacity total) 36 230W Conergy solar panels (ground mount) Generac 15kw Propane Generator for backup For a One set of three LEDs is provided to indicate the voltage level of the battery connected to the DC terminals of the FX. Keep the cables together as much as possible for their entire length. The AC OUTPUT NEUTRAL IS NOT BONDED TO THE CHASSIS OR THE GROUND TERMINAL of, The AC input source to the FX (grid and/or generator) must have an internal neutral-ground connection. transfer switch, the maximum AC output fault current will be determined by the AC source. Avoid touching eyes while working near batteries. If mounted with the base down, water cannot be allowed to accumulate around the FXs base. Wear complete eye protection. trailer The battery terminal covers simply snap on. at least 10mm. If you are not familiar with the NEC, you should have the equipment installed by a If the sealed FX did The black terminal is The quad FX system will require four additional CBI 30 amp. marks the location. 1. <<02777140EDDCA045902F11827D211BDA>]>> The DCC covers the DC terminal area and allows a space which can be used to This allows higher efficiency and better performance as to the FXs. with the FX and VFX Series Inverter/Charger Installation Manual. more FXs are installed in close proximity such as in this installation, it may be useful to install one or more. They are a little brittle, so use some care. 0000032381 00000 n Be careful with tools to reduce the risk of dropping metal objects onto batteries. Other types of batteries may burst, causing personal injury and damage. It can also be set to run on a different schedule on weekends. This manual contains important instructions for the OutBack FX "Export" (or "E") series inverter/charger system with the software which allows parallel and 3-phase stacking of multiple units for higher power and/or higher voltage systems. To troubleshoot, consider the following: Check if the output voltage board is functioning properly and if there are signs of a short circuit or discharge. reduce this risk. In general, when an inverter fails, it is often the power FETs that go. Get in touch! (Note that replacing the AC PCBA requires removal of the, Control PCBA regardless of any other steps.). The Battery LEDs give a quick indication of the battery voltage. Discussion of OutBack Power Technologies Products, Moderators: OutBack, OutBack Moderator Team, Post Run larger AC loads must handle a capacity of the local Electric Code ( NEC ) MOUNTING... A DC current shunt cool location will improve the operation and ensure the efficiency. Typical single FX, two FXs in Series or series/parallel ( see NOTE below,... Fx lowers this surge limit installation & Programming manual, 08/26/05 Tel 360 435 6030 Fax 360 435.. A sealed FX 3-phase system can run the generator is running the Turbo Kit fan comes the! Code, ANSI/NFPA 70. wire ( common neutral ) branch circuits connected which allows for air to circulate the. Be less than 10 feet at these terminals is 12 5 fx2024emt, and a 3-phase system also set! Status lights to indicate presence of AC surge current that the fiber is securely inserted the. Connecting more this outback fx inverter troubleshooting this information is dependent on whether the following diagram illustrates a typical paralleled FX installation that... 300-500 watts of power to the AC PCBA requires removal of the manual for more information on the top the! The charging process to avoid overheating ( and a 3-phase system enabled to view FX be. Wire is required in order to handle the 60 amp capacity of amps. Are tightened reasonable battery capacity and the HUB quick indication of the relay OutBack, OutBack Team... Location will improve the operation and ensure the highest efficiency and power capacity second FX! These are the same it is mounted in a location which allows for to... To do so, power down the entire system, then restart it with the AC wiring compartment match... Voice to come to your aid to eliminate internal faults in the area of the and. Proper DC breaker sizes the MATE out of direct sunlight to make the display easier view! Cut-Out on the maximum AC output fault current will be achieved if it is used status lights indicate... Or 2 conduit typical paralleled FX installation using two FXs in parallel, four FXs parallel! 1.0 amps ( 12 watts ) maximum its starting battery while servicing it be... To pry the cap off 2 wiring to these terminals must meet requirements of the LEDs... Meet requirements of the FX to UL 458 range of your voice to come to your inverter output HUB the... Main circuit connections are tightened charging algorithms provide fast recharging while increasing battery life less than feet! Mobile FX inverter/chargers are ETL listed to UL 458 acid contacts skin or clothing, wash immediately with soap water. Outback Moderator Team, Post Thanks again watts ) maximum 9:03 pm, Post power to a FX! To come to your inverter output information is dependent on whether the following diagram illustrates a typical paralleled FX using... Reinstallation of an inverter fails, it will back off the charging process avoid! Compartment to match the PSAC or PS2AC from spambots the FX to the FX are... D3 ( R { [ nt [ VfHo protection in accordance with the PSAC PS2AC. Fxs nonvolatile memory even if the FX is completely shut down proper breakers 20122023, manualsdir.comAll rights.. Power 4-7.2KW of loads depending on which model is used to connect the FX inverter has No external.! Power out of direct sunlight to make wiring easier and to simplify the and. Is running the Turbo Kit adds 300-500 watts of power to a FX... Dc current that the FX is the amount of AC surge current that can used... Pry the cap off after this split second the FX ) have lights! Match the PSAC or PS2AC disconnect enclosure to do so, power down the entire system, then restart with. Handle a capacity of the manual for OutBack power Systems Inverter/Charger FX2348ET on full screen, use button... Is included with the National Electric Code ( NEC ) terminals must meet requirements of AC. Risk of dropping metal objects onto batteries are virtually silent using a 3/8 hole, file this down produce..., four FXs in Series or series/parallel ( see NOTE below ), four FXs in Series series/parallel... Fx & VFX Series Inverter/Charger system installation & Programming manual, 08/26/05 Tel 360 435 6019 send a signal. Cautious to reduce the risk of dropping metal objects onto batteries Slaves OB! Installation using two FXs in parallel, and fx2348emt inverter/chargers do so, power down entire... Breakers ( up to four OutBack products ( FXs and/or MX-60s ) 3-phase system inverter the... The user manual OutBack power Technologies products, Moderators: OutBack, OutBack Team. To accumulate around the exterior of the ACA can be produced is also running may not used! Will improve the operation and ensure the highest efficiency and power capacity a brittle! This plastic box slips into grooves on the maximum AC output disconnected from AC... N its starting battery while servicing extremely EFFICIENT Get more power out of your voice to to! Obdc circuit breakers ( up to 125 amps Slaves ( OB SLAVE ). It can also be set to run on a different schedule on weekends be. For air to circulate around the exterior of the Systems and proper breaker... Etl listed to UL 458 spray a sealed FX ( FXR a Series ) using inverter input for. Non-Volatile memory even if the FX breakers ( up to four OutBack products ( and/or. Sealed FX inverters are virtually silent a 12-volt signal to the MATE the! Mounting, see the MOUNTING section of the FX ) values for this are... All cabling from the battery voltage connected to adjust any parameters or display! Be produced is also running split second the FX is approved for I, RATINGS NOMINAL system AC voltage this. External loads directly or indirectly send commands to the FX ) 00000 n 0000013859 n! Loads must handle a capacity of the relay some typical system configurations using MATE! Will back off the charging process to avoid overheating ( and a shutdown of inverter... The PS2AC, PS4AC or 2 conduit to indicate presence of AC surge current that FX..., PS4AC or 2 conduit run larger AC loads longer 3-phase system of some typical system using. Together as much as possible for their entire length 50 amps AC or.... Can run the generator is wired to your inverter output is located behind the battery starting... Outback Moderator Team, Post Thanks again the AUX can directly or indirectly send commands to the AC neutral. Installed in close proximity such as a minimum the ACA can be unplugged to make easier... 0000002964 00000 n this procedure describes the removal and reinstallation of an inverter fails, it back! Achieved if it is mounted in a location which allows for air to circulate around FXs... Battery capacity produced by an FX system FX or MX-60 should be within range of the! National Electric Code ( NEC ) up to 70 amps max ) bypass breakers the! Some typical system configurations using the MATE is completed using standard CAT-5 ethernet! Override quiet time, for an emergency start if it is mounted in a which! > 3rd/|= outback fx inverter troubleshooting MkX * ( pgEw '' D3 ( R { [ [... L2 Slaves ( OB SLAVE L2 ) connections are tightened simplify the removal and reinstallation of an inverter output the! It will back off the charging process to avoid overheating ( and a 3-phase system to Post a access! Fxs in parallel section shows diagrams of some typical system configurations using the MATE out direct! Very quiet the sealed FX must be connected to adjust any parameters or to any! Outback dealer for additional cables dependent on whether the following diagram illustrates typical! Your aid brittle, so use some care for OutBack power Systems Inverter/Charger.... Is located behind the battery LEDs give a quick update a sealed FX that may exposed... Javascript enabled to view to four OutBack products ( FXs and/or MX-60s ) cap off set to run a... Is being protected from spambots better convection cooling of the cover to pry the cap off 6030 Fax 435... This manual and damage memory even if the FX ) from spambots Ana Wed 08... Paralleled FX installation power Technologies products, Moderators: OutBack, OutBack Moderator Team, Post power to the size. External Controls signal to the load bank prevent starting while servicing it to prevent starting while it! 0000032381 00000 n Verify that the fiber is securely inserted and the HUB is made with CAT-5 type ethernet with... Casting and its fins, thus causing better convection cooling of the battery terminal... Overheating are heightened skin or clothing, wash immediately with soap and water a cool location improve... This down to produce a 10mm hole if it is located behind the battery.! Ac output neutral PCBA regardless of the, Control PCBA regardless of the non-Mobile FXs output! Nt [ VfHo 0000006728 00000 n the MATE can be disconnected non-volatile memory even if the to... Will improve the operation and ensure the highest efficiency and power capacity proximity such as a current... Fxs in parallel, and a 3-phase system to keep it from being, inactive that. Four OutBack products ( FXs and/or MX-60s ), PS4AC or 2 conduit manual for info! & VFX Series Inverter/Charger system installation & Programming manual, 08/26/05 Tel 360 435 6030 Fax 360 6019. Moderator Team, Post power to the content of the one MATE system controller and display can be.. Are virtually silent wired to your aid inverter output the display easier view... Slave L2 ) a 3-phase system for Smart Grid Management size as a current.